Download ANSI-IEEE 1010-1987 Guide for Control of Hydroelectric Power PDF

Read or Download ANSI-IEEE 1010-1987 Guide for Control of Hydroelectric Power Plants PDF

Similar plants books

The IEA/SSPS Solar Thermal Power Plants — Facts and Figures — Final Report of the International Test and Evaluation Team (ITET): Volume 1: Central Receiver System (CRS)

The Project's beginning by reason of the so-called "first oil crisis", the curiosity in sun electrical energy iteration rose sharply after 1973. The sun ther­ mal means of fixing the matter used to be appealing as the major job was once just to change the fossil gas via a "solar gasoline" in an different­ clever traditional thermal energy plant -that used to be at the very least what many proposal at the moment.

Mountain Ecosystems: Studies in Treeline Ecology

Mountain ecosystems belong to the main endangered ecosystems on this planet. specially, the treeline ecotone acts as a hallmark for environmental swap. notwithstanding, ecological procedures within the treeline ecotone are usually not but thoroughly understood. The reports supplied during this publication could give a contribution to a greater knowing of the interactions among crops, weather, fauna, and soils within the treeline ecotone.

400 Floral Motifs for Designers, Needleworkers and Craftspeople

Treasury of infrequent Victorian-era designs for borders, wreaths, cushion squares, sprays, and different tasks. comprises styles for verbena, strawberry, lily, and lots of extra.

Additional resources for ANSI-IEEE 1010-1987 Guide for Control of Hydroelectric Power Plants

Example text

Inlet valves are desirable for each unit if one penstock is used for two or more turbines. Plants having intake gates or valves should have their controls interfaced with the unitÕs control system. The gates are normally closed for one of two purposesÑmaintenance or emergencyÑbut not during normal operation. An emergency can include a unit run-away due to such things as load rejection and failure of the wicket gates to close. It is critical that the intake be capable of closing under all ßow conditions.

27SV Converter sync voltage failure A 33 Thyristor cubicle door open P, A Trips static starter*, alarms. 33RS Phase reversing switch wrong position P, A Trips static starter*, alarms. 48 Start/stop sequence incomplete (time exceeded) P, A Trips static starter*, alarms. 49 Cooling oil high temp P, A Trips static starter*, alarms. 50G Starter ground fault P, A Trips static starter*, alarms. 51 Starter overcurrent P, A Trips static starter*, alarms. 52b Cooling system feeder breaker tripped P, A Trips static starter*, alarms.

N(ref) Speed reference indication I H-3 Typically derived from a potentiometer or synchro ganged to the motor drive. 65PM-LS Power reference motor drive limit switches C, I H-4 Adjustable limit switches are used to preposition the power reference prior to starting the unit and prior to transferring from generate mode to synchronous condenser mode. ÒEnd-of-travelÓ limit switches are used for illumination of lamps at remote raise/lower control switches or pushbuttons. P(ref) Power reference indication I H-4 Typically derived from a potentiometer or synchro ganged to the motor drive.